      Stap 1 — Resistor fault, base

      One of the frequent failures is the resistor insulation fault. This is the case when the device is energized and the differential circuit breaker "trips". There is unfortunately not much to do, except to change the resistance.

      Stap 2 — On/off device

      The problem was that the water would not heat up when the switch was turned on! After successfully testing the resistance and continuity of the power supply at the base, the remaining element that could be a problem is the M/A device located in the tank.