Stap 5
Fix Overheating Error in Dyson AM09, Managing the wires: stap 0, afbeelding 1 van 3 Fix Overheating Error in Dyson AM09, Managing the wires: stap 0, afbeelding 2 van 3 Fix Overheating Error in Dyson AM09, Managing the wires: stap 0, afbeelding 3 van 3
Managing the wires
  • Two T8 screws hold down the cover over this. The blade connectors have a little tab lock that must be pushed while pulling them apart.

  • The black wire is for the temperature sensors.

  • The white wire is for power (disconnects near the base, under a woven sleeve that slides out of the way. You don't need to touch the heatsink). The servo connector pulls apart easily.

  • The arrows show the 4 places to disconnect the wires so you can separate the top from the bottom. The white connectors under the sheath may also have a tiny lock tab that you need to push in while pulling them apart. Make sure to take note of how the wires run before take off the cover.

  • Make sure to mark the black wires before disconnecting so that reconnect them correctly when putting it back together. (Photos in reverse order).