-[* black] Insert the flat-blade screwdriver into the hole on the right side of the frame, and rotate the white shaft of the Ink System Unit.
+[* black] *Release the Carriage lock, and move the Carriage Unit to the center by inserting the flat-blade screwdriver into the hole on the right side of the frame, and rotate the white shaft of the Ink System Unit.
+[* black] *Pull the right end of the CR Scale in the direction of the arrow, and remove the CR Scale from the tab on the Right CR Shaft Mounting Plate.
+[* black] *Draw out the right end of the CR Scale toward the left direction from the rear of the Carriage Unit.
+[* black] *Release the coil section of Torsion Spring 24.7 from the tab on the Left CR Shaft Mounting Plate with tweezers.
+[* black] *Remove Torsion Spring 24.7 from the CR Scale following the next steps: 1. Bring the coil section to an upright position. 2. Push downwards to release foot 1 from the cutout on the Left CR Shaft Mounting Plate. 3. Turn the coil section counterclockwise. 4. Remove Torsion Spring 24.7 from the hole on the CR Scale.
+[* black] *Turn the CR Scale 90°, and remove it from the tab on the Left CR Shaft Mounting Plate.