Refrigerator cool but not cold

Whirlpool GS5SHAXNB02 side-by-side fridge. The freezer side maintains a temp of about 50°. The evaporator coils (cooling) have NO frost on them, only the very top line where the thermostat clips on is frosted. The condenser fan sounds like it is running, what now?

Block Image

Beantwoord deze vraag Dit probleem heb ik ook

Is dit een goede vraag?

Score 0
Voeg een opmerking toe

Nintendo Switch-kits

Een snelle oplossing die je weer mee laat doen

Koop Switchkits

Nintendo Switch-kits

Een snelle oplossing die je weer mee laat doen

Koop Switchkits

2 Antwoorden

Het nuttigste antwoord

Hi @tommysparks1 ,

Have you checked the thermometer? ;-)

What is the temperature in the refrigerator section?

Is the compressor running? Have you checked that the refrigerator is not is the defrost cycle?

The compressor and evaporator fan will be switched off for 15-25 minutes to defrost the evap unit. After this the compressor and fan will be switched on again to cool things back down. This takes a bit of time to achieve but the freezer should never be at 50 F. If the compressor is not running then the defrost thermostat may be the problem. It should operate at 32 F to tell the control board to turn off the defrost cycle and to start the compressor/evap fan again The condenser fan, near the compressor can operate in the defrost cycle.

If the compressor is running, is the evaporator fan operating? With the freezer door open, manually operate the freezer door switch. The light should go out and the fan should start operating.

Was dit antwoord nuttig?

Score 1
Voeg een opmerking toe

Great pic. It says a lot! The issue is in the sealed system. Either there is a refgerant leak, a restriction in the flow of refrigerant or the compressor isn’t pumping properly. The frost pattern on the evaporator coils is very helpful in diagnosing a sealed system issue. Unfortunately, it’s not a repair that an average DIYer can do. The EPA requires that only certified technicians can enter the sealed system. You would need to have a quialified refrigeration technician to do the repairs. .

Was dit antwoord nuttig?

Score 1