Hi There,

I got a Marantz SR-60 tuner and amplifier that started to blow the 1.25 amp fuse on the power switch and supply board.

Is there a way of getting a board like this, the spec number on the board is:P904 yk058j1 52-2.

When you turn on the unit, it goes on pre-on then, if you turn the unit on and off a few times it just blows the fuse. Not sure it would be the mauve, the board or the fuse.

Would anyone have an idea of what's causing the problem.

Eddie

Thanks

Beantwoord! Bekijk het antwoord Dit probleem heb ik ook

Is dit een goede vraag?

Score -1
Voeg een opmerking toe

1 Antwoord

Gekozen oplossing

It sounds like bad caps or a bad powersupply. Here is the service manul. Take a look and check it out. If you can not get a whole new logic board, all the components are listed, so you should have no trouble fixing it. Good Luck

Was dit antwoord nuttig?

Score 4

2 opmerkingen:

I have SR60 , with one channel intermittent disorted sound, what the cause ? can I have the service manual. thanks

door

you can contact me by email, my address is in my user profile. I may still have it....;-)

door

Voeg een opmerking toe