I think machine has blown fuse

I think machine has blown fuse. The cord got caught while vacuuming, stopped and will not turn on again. There was no noise or burning smell. Nothing to indicate motor failure. The cord is undamaged. I suspect the machine plug became dislodged from the power socket or something similar to make it blow a fuse. What type of fuse do I need please? Is this something an electrician could fix as I live in a remote area , need the machine for daily use for medical reasons and for medical reason cannot use another machine in the meantime until this one is fixed.

Beantwoord deze vraag Dit probleem heb ik ook

Is dit een goede vraag?

Score 0
3 opmerkingen

Hi,

After fiddling with the actuator and power cord the machine works again , and it the cord is at a certain angle the machine stops until the angle is corrected. So I think you are right, the issue is with the power cord. Question: Would it be possible to fix the wiring within the cord retract as I cant find a replacement cord retract as dyson no longer stock parts and I have been unable to source elsewhere.

door

Hi,

After fiddling with the actuator and power cord the machine works again , and it the cord is at a certain angle the machine stops until the angle is corrected. So I think you are right, the issue is with the power cord. Question: Would it be possible to fix the wiring within the cord retract as I cant find a replacement cord retract as dyson no longer stock parts and I have been unable to source elsewhere.

door

can somebody please help me. The machine stopped working again. I fiddled with the cord and something blew around the area where the cord comes out from the machine. I need t vacum daily for medical reaon and cannot borrow or buy a ne w vacum for medical reasons.

door

Voeg een opmerking toe

1 Antwoord

Het nuttigste antwoord

Hi Gemma,

Please look into this post: How do I replace the damaged power cord

It lists the disassembly instructions for the power cable retraction system - along with replacement.

When reviewing your symptom and “possible” cause being “cable-displacement” - THIS REALLY STOOD OUT! I hope it helps some.