Wat je nodig hebt

  1. ProScan PLT7223G Front Facing Camera Replacement, Front Facing Camera: stap 1, afbeelding 1 van 1
    • Remove both 4 mm screws on the top of the tablet with a PH00 screw driver.

    Vraag FixBot

    Voeg opmerking toe

  2. ProScan PLT7223G Front Facing Camera Replacement: stap 2, afbeelding 1 van 1
    • Use the blue plastic opening tool to pry open the tablet.

    • You will hear popping sounds. That's okay.

    • Be careful when using the blue plastic opening tool on the side of the device near the speakers, as there is a wire here that connects the speakers to the motherboard.

    Vraag FixBot

    Voeg opmerking toe

  3. ProScan PLT7223G Front Facing Camera Replacement: stap 3, afbeelding 1 van 1
    • With a spudger, flip up the ZIF connector that connects the camera's ribbon cable to the motherboard. This will release the ribbon cable.

    Vraag FixBot

    Voeg opmerking toe

  4. ProScan PLT7223G Front Facing Camera Replacement: stap 4, afbeelding 1 van 1
    • Remove the black tape holding down the ribbon cable.

    Vraag FixBot

    Voeg opmerking toe

  5. ProScan PLT7223G Front Facing Camera Replacement: stap 5, afbeelding 1 van 1
    • Remove camera.

    Vraag FixBot

    Voeg opmerking toe

Conclusie

To reassemble your device, follow these instructions in reverse order.