Inleiding

Problems with the beat pad are common with this device. Use this guide to replace a defective beat pad sensor.

Onderdelen

  1. Remove all the selector knob covers by pulling them off.
    • Remove all the selector knob covers by pulling them off.

  2. Using needle nose pliers, remove the washers from the four corner selector knobs.
    • Using needle nose pliers, remove the washers from the four corner selector knobs.

  3. Flip the device over. Using a Philips #2 screw driver, remove the fourteen 10.3 mm black screws holding the back panel in place.
    • Flip the device over. Using a Philips #2 screw driver, remove the fourteen 10.3 mm black screws holding the back panel in place.

  4. Gratis verzending van alle bestellingen van meer dan US$ 100,00 of met een Pro Tech Toolkit!

    Doorblader onze winkel

    Ooit iets gerepareerd? Je bent een genie.

    Deel je reparatie met #ImAGenius

    We zijn allemaal genieën

    Deel je reparatie met #ImAGenius

  5. Carefully flip the device to the front making sure you secure the face plate and the chassis together. Please use care in following the step above to avoid ripping the ribbon cables connecting the two sides. Please use care in following the step above to avoid ripping the ribbon cables connecting the two sides.
    • Carefully flip the device to the front making sure you secure the face plate and the chassis together.

    • Please use care in following the step above to avoid ripping the ribbon cables connecting the two sides.

  6. Rotate the device 180 degrees and carefully remove the face plate by slightly lifting the screen side towards you and then sliding the bottom out from under the keys. Use care when doing the step above so that the ribbon connectors which connect the top of the chassis to the top of the face plate are not damaged. Use care when doing the step above so that the ribbon connectors which connect the top of the chassis to the top of the face plate are not damaged.
    • Rotate the device 180 degrees and carefully remove the face plate by slightly lifting the screen side towards you and then sliding the bottom out from under the keys.

    • Use care when doing the step above so that the ribbon connectors which connect the top of the chassis to the top of the face plate are not damaged.

  7. Using a Phillips #2 screwdriver, remove the thirteen 9.8 mm silver screws holding the mother board to the face plate.
    • Using a Phillips #2 screwdriver, remove the thirteen 9.8 mm silver screws holding the mother board to the face plate.

  8. Using a Phillips #2 screwdriver, remove the four 9.8mm screws holding in the base of the beat pad.
    • Using a Phillips #2 screwdriver, remove the four 9.8mm screws holding in the base of the beat pad.

  9. Slightly lift the mother board near the edge of the beat pads and wiggle the beat pad ribbon connector free. Slightly lift the mother board near the edge of the beat pads and wiggle the beat pad ribbon connector free.
    • Slightly lift the mother board near the edge of the beat pads and wiggle the beat pad ribbon connector free.

  10. Remove the beat pad sensor from the face plate. Remove the beat pad sensor from the face plate.
    • Remove the beat pad sensor from the face plate.

Conclusie

To reassemble your device, follow these instructions in reverse order.

Serbinder Singh

Lid sinds: 30-01-13

72 Reputatie

3 handleidingen geschreven

Team

Cal Poly, Team 20-6, Maness Winter 2013 Lid van Cal Poly, Team 20-6, Maness Winter 2013

CPSU-MANESS-W13S20G6

5 Leden

6 handleidingen geschreven

Weergavestatistieken:

Afgelopen 24 Uren: 1

Afgelopen 7 Dagen: 6

Afgelopen 30 Dagen: 20

Altijd: 3,052