Vind antwoorden in dit document
We hebben alle pagina’s op 76 al doorgenomen, zodat jij dat niet hoeft te doen. Stel je vraag en krijg meteen antwoord.
Robin Generator R650
Technical Data & Overhaul Instructions SERVICE MANUAL
CONTENTS
| Section | Title | Page | |
|---|---|---|---|
| 1. SPECIFICATIONS ....................................... | 1 | ||
| 2. PERFORMANCE CURVES ................................ | 2 | ||
| 2-1 | ACOutput ........................................ | 2 | |
| 2-2 | DCOutput ........................................ | 2 | |
| 3. | FEATURES ............................................ | 3 | |
| 4. | GENERAL DESCRIPTION OF THE GENERATOR ............ | 4 | |
| 4- 1 | Component Identification ............................ | 4 | |
| 4-2 | Location of Serial Number, Specification and | ||
| Specification Number. ............................... | 7 | ||
| 5. | CONSTRUCTION AND FUNCTION OF THE GENERATOR ..... | 8 | |
| 5-1 | Construction | 8 | |
| 5-2 | ...................................... Function of Each Component ......................... | 9 | |
| 5-3 | Description of Generator Operation ..................... | 12 | |
| 5-4 | Electronic Ignition System ............................ | 14 | |
| 6. | SAFETY PRECAUTIONS ................................. | 15 | |
| 7. | RANGE OF APPLICATIONS .............................. | 16 | |
| 7-1 | ACOutput ........................................ | 16 | |
| 7-2 | DCOutput ........................................ | 18 | |
| 8. | MEASURING PROCEDURES ................ | a. | 20 |
| 8-1 | Measuring Instruments ............................... | 20 | |
| 8-2 | Measuring AC Output ............................... | 22 | |
| 8-3 | Measuring DC Output ............................... | 22 | |
| 8-4 | Measuring Insulation Resistance ........................ | 22 | |
| 9. | CHECKING FUNCTIONAL MEMBERS ...................... | 24 | |
| 9-1 | Control Panel ...................................... | 24 | |
| 9-2 | Stator ............................................ | 26 | |
| 9-3 | Rotor ............................................ | 28 | |
| 9-4 | Ignition Coil ....................................... | 29 | |
| 9-5 | Condenser ........................................ | 29 | |
| 9-6 | Diode Rectifier. .................................... | 29 | |
| 9-7 | Micro-Switch ...................................... | 30 | |
| 10. | DISASSEMBLY AND ASSEMBLY .......................... | 31 | |
| 10-1 | Preparation and Precautions ........................... | 31 | |
| 10-2 | Special Tools for Disassembly and Assembly .............. | 31 | |
| 10-3 | Disassembly Sequence ............................... | 32 | |
| 10-4 | Assembly Procedure ................................. | 47 | |
| 10-5 | Carburetor ........................................ | 58 | |
| 10-6 | Frequency Changeover System ......................... | 61 |
Table Caption: This table is a table of contents for a generator service manual, outlining specifications, performance curves, features, general description, construction and function, safety precautions, applications, measuring procedures, functional member checks, and disassembly/assembly instructions.
| Section | Title | Page |
|---|---|---|
| 11. | TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 63 |
| 11- 1 Engine does not start or engine does not run normally. . . . . | 63 | |
| 11-2 Voltmeter does not work or pilot lamp does not turn on. No AC output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 66 | |
| 11-3 No DCoutput . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 69 | |
| 11-4 0utput voltage is normal at no-load, but generator won't work on-load. . . . . . . . . . . . . . . . . . . | 69 | |
| 12. | CIRCUIT DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 71 |
| 12-1 50Hz/GOHz Variable Type . . . . . . . . . . . . . . . . . . . . . . . . . . | 71 | |
| 12-2 60Hz-120V Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 71 |
Table Caption: This table outlines the troubleshooting procedures for various generator issues, starting on page 63, and then provides circuit diagrams for different generator types beginning on page 71.
1. SPECIFICATIONS
| ENGINE | Type | 1 I | Forced air-cooled, &troke, side valve, gasoline engine | |
|---|---|---|---|---|
| Displacement | 78 cc (4.76 cu. in.) | |||
| Fuel tank capacity | 1 | 2 lit. (0.53 U.S. gal.) | ||
| Oil pan capacity | I I | 350 cc (0.75 U.S. pints) | ||
| Ignition system | I | Solid state ignition | ||
| Starting system | Recoil starter | |||
| Rated continuous operating hours | ( | Approx. 4.5 hours (50Hz) Approx. 4.0 hours (60Hz) | ||
| GENERATOR | Type | I | 2-pole revolving field type | |
| Exciting system | I | Self-exciting | ||
| y regulating | 1 | Condenser type | ||
| aximum output | I | 55OW/65OW | 650W | |
| Rated output | I I | 45ow/55ow | 550w | |
| AC frequency | I | 50Hz/60Hz | 60Hz | |
| AC voltage | I | 110,220,24OV | 12ov | |
| DC output | 12V-1OOW (8.3A) | |||
| AC receptacle | 1 | Standard: 2 ea. (Special: 1 ea.) | ||
| DC terminal | I | A couple | ||
| Over current protection | 1 | Circuit breaker | ||
| Voltmeter | I | Standard | ||
| Pilot lamp | Standard | |||
| Dimensions (L x W x H) | 370 x 265 x 345 mm | (14.6 x 10.4 x 13.6 in.) | ||
| Dry weight | 18.5 kg (40.7 Ibs.) |
Table Caption: This table compares the specifications of two generators, highlighting differences in their maximum and rated output, AC frequency, and AC voltage.
2. PERFORMANCE CURVES
2-l AC OUTPUT
'c
. 50Hz/60He220V Type OUTPUT
Max. . . .
550W/50Hz, 650W/60Hz
Rated . .
450W/50Hz, 550W/60Hz
2-2 DC OUTPUT
l 60 Hz- 12OV Type
OUTPUT
Max.
. . . . . . . . . . . . . . .65OW
Rated
. . . . . . . . . . . . . .55OW
Rated voltage
.............
12V
Rated current
............
8.3A
Rated output
............
1OOW
3. FEATURES
- l Exhaust Fan Cooling System for low body temperatures, low noise, longer engine life and reliable performance.
- 0 Large 78 cc 4-Stroke Engine provides enough power for constant 55OW (at 60 Hz) rated output.
- 0 Simple One-Touch Engine Control Switch with the engine and fuel on/off levers and choke all integrated into one switch.
- 0 Easy and Reliable Starting with pointless ignition. This generator is also a brush-less type generator for maintenance-free operation.
- l Simple Design for a clean appearance and easy maintenance.
- 0 Compact and Lightweight with an easy one-hand carrying handle grip. This generator also offers a high power-to-weight ratio and economical operation.
- 0 Circuit Breaker Protection for safe operation. Replacement of fuses is not necessary in case of an overload.
- 0 Unique Dual Output Design so that two separate A.C. and D.C. electrical appliances can be used at the same time.
- 0 Frequency Changeover Switch enables changing output frequency from 50 Hz to 60 Hz.
- 0 Optional Oil Warning System automatically stops the
Meld je gratis aan bij iFixit om het volledige document te lezen (76 pagina's)
We vragen je om een gratis account aan te maken, zodat we bots buiten de deur kunnen houden en iFixit voor mensen blijft.