Unilite Curing Light

Installation Guide

CONTENTS

Unpacking ........................................................1
Junction Box Tubing Connections.................1
Junction Box Wiring Connections.................3
Delivery Head Tubing & Electrical Connections..................................................3
Assistant's Instrument Head Tubing & Electrical Connections.................................4
Curing Light Operation ...................................5

Table Caption: This table lists various steps involved in setting up or assembling equipment, indicating the page number on which each step can be found. The steps include unpacking, connecting tubing and wiring to different components, and operating a curing light.

UNPACKING

EQUIPMENT ALERT

To avoid damage, do not use a knife or sharp object to open packaging.

  • (1) Carefully remove all enclosed components from packaging and inspect for shipping damage. If damage is apparent, file a Concealed Damage Report with the carrier.

1

JUNCTION BOX TUBING CONNECTIONS

(1)Remove junction box cover (1, Figure 1).
(2)Align and velcro two strips of velcro hook (2) onto two strips of velcro loop (3).
(3)Peel protective backing (A) from back side of two velcro hook (2) strips; then position mounting box (4) on top of universal power supply (5) in orienta- tion shown in illustration. Press down firmly on mounting box to ensure adhesive backing of velcro adheres to universal power supply.
(4)If necessary, remove two screws (B) and cover (C) from chassis (D).
(5)Connect 1/4 in. yellow tubing (6) [from umbilical] fitting (7) [labeled port '1'] of pressure switch with 1/4 in. sleeve clamp (8).
(6)Remove plug (9) and gasket (10) from connector ting (11) [on rear of 80 PSI pressure gauge] .
(7)Install new gasket (12) and 10-32 x 1/4 in. O.D. fit- ting (13) on connector fitting (11).
(8)Connect 1/4 in. yellow tubing (14) [supplied with kit] to fitting (13) [on rear of 80 PSI pressure gauge] with 1/4 in. sleeve clamp (15).
(9)Connect remaining end of 1/4 in. yellow tubing (14) to fitting (16) [labeled port '2'] of pressure switch with 1/4 in. sleeve clamp (17).

Table Caption: This table provides a step-by-step guide for a technical procedure, likely involving the installation or replacement of components. It details actions such as removing covers, attaching parts with velcro, connecting tubing, and modifying fittings, referencing specific numbered parts and illustrations.

UNILITE CURING LIGHT

JUNCTION BOX WIRING CONNECTIONS

  • (1) Connect power harness (1, Figure 2) to center connector (2) [labeled 'CURING LIGHT'] of universal power supply.
  • (2) Connect blue wire (3) [from umbilical] to Terminal '1' of relay timer (4).
  • (3) Connect brown wire (5) [from umbilical] to Terminal '3' of relay timer (4).
  • (4) Connect yellow wire (6) [from umbilical] to Terminal '5' of relay timer (4).
  • (5) Connect violet wire (7) [from umbilical] to Terminal '8' of relay timer (4).
  • (6)