This is an older family of Saeco devices. The main difference between Odea and Talea is the SBS brewing system of the Talea line. The model designation of the Odea is SUP031 **, the Talea SUP032 **.

2 Vragen Bekijk alle

Saeco Odea Giro Flashing thermostat light.

My Saeco Odea Giro machine has a blinking thermostat light at startup implying the boiler is heating but it never stops blinking and I can’t initiate a brew.

I don’t have easy access to a service centre so I would be grateful if anyone could point me in the right direction on how to solve it.

Beantwoord deze vraag Dit probleem heb ik ook

Is dit een goede vraag?

Score 0
Voeg een opmerking toe

2 Antwoorden

Het nuttigste antwoord

@seychellian First help: use the test mode and proof, if the heating really works. If not open the machine. Look for the heating and measure its resistance, it should be 40 Ohm for 230 V models. (Or 10 Ohm for 120 V). If not: replace the heater. Describe your observations, good luck!

Was dit antwoord nuttig?

Score 1

1 Opmerking:

Test mode is telling me that the heating element isn’t working :(

door

Voeg een opmerking toe

Oh, so you will replace the heating. Open the device, look for the heating. I found the service manual for Odea - but it's in german. The pictures in page 45 will help you. In english here

Was dit antwoord nuttig?

Score 0
Voeg een opmerking toe