Ac not blowing cold air.

Had econ light on, found broken grownd wire to pressure switch. Fixed, econ light now off but still no cold air. Have about 70psi on low side of freon and 9vdc going to compressor. Compressor has a solenoid valve, and it does have continuity. Please help, thanks in advance.

Beantwoord deze vraag Dit probleem heb ik ook

Is dit een goede vraag?

Score 0
Voeg een opmerking toe

1 Antwoord

Het nuttigste antwoord

Measure resistance of clutch coil. It should be very low, around 3 ohms. If it's open, the thermal fuse is blown and not a diy repair with some epoxied permanently. With ac turned on, the power wire to the compressor clutch coil should be battery voltage. If the connector is a two wire configuration, measure power to its ground wire and to engine block ground. 70 psi is well above the pressure sensor value to allow power to the compressor. If damage occurs with refrigerant loss, standby pressures below approximately 40 psi will be detected by the pressure sensor, sending a disable signal to the ecm to disable power to the compressor. Loss of refrigerant means loss of lubricating oil. If allowed to run with loss of refrigerant, the compressor will self destruct.

Was dit antwoord nuttig?

Score 1
Voeg een opmerking toe