There are ten 8mm bolts holding the valve cover down

These bolts must be removed from outside to inside, working diagonally

On reassembly these bolts must be torqued in two stages, working from inside to outside

On the first stage, tighten to 2 Nm

On the second stage, tighten to 7 Nm

Disconnect the vacuum hose going to the intake

It is recommended that you change the valve cover gasket before reassembly