-[* black] ''edit'': the correct temperature is almost 180-200 °C because around the chip there is a little black protection that can go under the chip.
-[* black] Set a low air flow; 1 or 2 (on a 1 to 7 scale).
+[* black] ''Edit'': the correct temperature is almost 180-200 °C because around the chip there is a little black protection that can go under the chip.
+[* black] Set a low air flow: 1 or 2 (on a 1 to 7 scale).
[* black] Now, doing circular movement, you have to reflow for 4-5 minutes.
-[* icon_caution] Be careful to reflow only the wifi chip and not any of the surrounding ICs or circuits.
-[* black] After 5 minutes, decrease gradually the temperature from 200 to 0 °C
+[* icon_caution] Be careful to reflow only the Wi-Fi chip and not any of the surrounding ICs or circuits.
+[* black] After 5 minutes, gradually decrease the temperature from 200 to 0 °C.