Inleiding

A guide to remove power block from the Sega Dreamcast.

Onderdelen

Geen onderdelen nodig.

Verify that the console is disconnected from the AC outlet before you begin.
  • Verify that the console is disconnected from the AC outlet before you begin.

  • Flip the console over on its back.

  • Take note of your model number, in case replacement parts are needed.

Voeg opmerking toe

Remove the expansion bay by applying pressure to the small clip on the expansion bay while prying it away from the console.
  • Remove the expansion bay by applying pressure to the small clip on the expansion bay while prying it away from the console.

Voeg opmerking toe

  • Locate and remove all four black 12mm Phillips #02 screws from the underside of the console.

  • Note: Remove the expansion bay to locate the fourth screw

Voeg opmerking toe

  • Internal components can be loose. Be careful that they do not fall out when removing the cover.

  • Turn the console right side up.

  • Remove the top cover by gently lifting the upper portion of the console.

Voeg opmerking toe

  • Verify that the console is disconnected from the AC outlet before you begin. If you have just powered off the system, give the capacitors a few minutes to discharge before you begin working.

  • Remove the white female pin header by clamping the clip and pulling it up gently from the power board.

Voeg opmerking toe

  • Remove the two 10mm Philips #02 screws that are fastened to the power block.

Voeg opmerking toe

  • Do not bend the male pin header between the mounted head when you remove the power supply from the chassis.

  • Remove the power board by using both hands to gently lift the power board away from the console.

Voeg opmerking toe

  • Remove the clear plastic film that is tucked between the power supply and the chassis.

Voeg opmerking toe

Conclusie

To reassemble your device, follow these instructions in reverse order.

8 andere personen hebben deze handleiding voltooid.

wkwong

Lid sinds: 14-11-09

414 Reputatie

13 handleidingen geschreven

Team

Cal Poly, Team 5-1, Regan Fall 2009 Lid van Cal Poly, Team 5-1, Regan Fall 2009

CPSU-REGAN-F09S5G1

5 Leden

23 handleidingen geschreven

All symptoms of dead PSU can be occuring, if by accident flat ribbon cable between motherboard and controller board is disconnected. Check that cable if both ends is firmly plugged.

lauraiss lv - Antwoord

Hello There!

i turn on my dreamcast, No video, GD don´t spin, but the orange led barely shine, this happened many years ago (2003) , i just bought another DC in those days because i was in a hurry to end Grandia 2, and now i still have the damaged console in my room and im wondering if it is possible to fix it ...thanks!

Mardito Online - Antwoord

Very good and Panico

Mikesin - Antwoord

Voeg opmerking toe