Ga door naar hoofdinhoud

Milwaukee M12 2407-20 Forward/Reverse Shuttle Replacement

Wat je nodig hebt

  1. Milwaukee M12 2407-20 Forward/Reverse Shuttle Replacement, Outer Casing: stap 1, afbeelding 1 van 1
    • Remove each of the seven 14mm Pan Hd. T-10 ST screws on one side of the housing assembly using the T10 screwdriver.

  2. Milwaukee M12 2407-20 Forward/Reverse Shuttle Replacement: stap 2, afbeelding 1 van 1
    • Remove metal clip located at the base of the drill, where the battery is to be inserted.

    • You may need to use a spudger if the clip is too difficult to remove with your fingers.

  3. Milwaukee M12 2407-20 Forward/Reverse Shuttle Replacement, Forward/Reverse Shuttle: stap 3, afbeelding 1 van 3 Milwaukee M12 2407-20 Forward/Reverse Shuttle Replacement, Forward/Reverse Shuttle: stap 3, afbeelding 2 van 3 Milwaukee M12 2407-20 Forward/Reverse Shuttle Replacement, Forward/Reverse Shuttle: stap 3, afbeelding 3 van 3
    • Use both hands to lift and remove the gear case assembly from the shell casing.

    • Set the gear case assembly aside.

  4. Milwaukee M12 2407-20 Forward/Reverse Shuttle Replacement: stap 4, afbeelding 1 van 1
    • While holding the shell in one hand, pull the end of the broken forward/reverse shuttle out of the casing.

    • Set the broken forward/reverse shuttle aside.

Conclusie

To reassemble your device, follow these instructions in reverse order.