Inleiding

This guide will show you how to remove both the axle and the handle, so that you can replace either one or both.

Gereedschap

Geen gereedschap nodig.

Onderdelen

Geen onderdelen nodig.

Assemble the required tools, including the Afridev tool and crescent wrenches. Assemble the required tools, including the Afridev tool and crescent wrenches.
  • Assemble the required tools, including the Afridev tool and crescent wrenches.

Voeg opmerking toe

Perform a water test on the pump, by raising and lowering the handle a full 40 strokes. A properly performing pump will yield greater than 10 liters. Perform a water test on the pump, by raising and lowering the handle a full 40 strokes. A properly performing pump will yield greater than 10 liters. Perform a water test on the pump, by raising and lowering the handle a full 40 strokes. A properly performing pump will yield greater than 10 liters.
  • Perform a water test on the pump, by raising and lowering the handle a full 40 strokes. A properly performing pump will yield greater than 10 liters.

Voeg opmerking toe

Loosen the bolt on front of the face plate with the Afridev tool. Remove the plate from the pump by lifting it straight up.
  • Loosen the bolt on front of the face plate with the Afridev tool.

  • Remove the plate from the pump by lifting it straight up.

Voeg opmerking toe

Insert the T-handle into the top cylinder of the exposed pump rod. Insert the T-handle into the top cylinder of the exposed pump rod. Insert the T-handle into the top cylinder of the exposed pump rod.
  • Insert the T-handle into the top cylinder of the exposed pump rod.

Voeg opmerking toe

Loosen the 2 bolts on either side of handle. It is not necessary to remove the bolt at this time; however, take caution to not let the bolt fall out of the handle.
  • Loosen the 2 bolts on either side of handle.

  • It is not necessary to remove the bolt at this time; however, take caution to not let the bolt fall out of the handle.

Voeg opmerking toe

Loosen the 2 bolts on either side of the head to remove the handle from the pump rod. It is not necessary to remove the bolt at this time; however, take caution to not let the bolt fall out of the handle. It is not necessary to remove the bolt at this time; however, take caution to not let the bolt fall out of the handle.
  • Loosen the 2 bolts on either side of the head to remove the handle from the pump rod.

  • It is not necessary to remove the bolt at this time; however, take caution to not let the bolt fall out of the handle.

Voeg opmerking toe

Lift the handle to a horizontal position. Lift the handle to a horizontal position.
  • Lift the handle to a horizontal position.

Voeg opmerking toe

While one person lifts up on the T-handle, remove the bolt and connection pieces. While one person lifts up on the T-handle, remove the bolt and connection pieces. While one person lifts up on the T-handle, remove the bolt and connection pieces.
  • While one person lifts up on the T-handle, remove the bolt and connection pieces.

Voeg opmerking toe

Remove the bolt and connection pieces from the handle. Set the bolt pieces in a sanitary place, such as a bucket, to prevent contamination. Set the bolt pieces in a sanitary place, such as a bucket, to prevent contamination.
  • Remove the bolt and connection pieces from the handle.

  • Set the bolt pieces in a sanitary place, such as a bucket, to prevent contamination.

Voeg opmerking toe

Remove the handle from the pump. Be sure to set the handle in a sanitary place to prevent contamination.
  • Remove the handle from the pump.

  • Be sure to set the handle in a sanitary place to prevent contamination.

Voeg opmerking toe

Conclusie

To reassemble your device, follow these instructions in reverse order.