BiPAP Focus Ventilator Service Manual
RESPIRONICS $ ^{®} $
BiPAP $ ^{\textregistered} $ Focus $ ^{\text{™}} $ Ventilator
SERVICE MANUAL
Copyright © 2006. Respironics, Inc. ALL RIGHTS RESERVED.
This work is protected under Title 17 of the United States copyright code and is the sole property of Respironics. No part of this document may be copied or otherwise reproduced, or stored in any electronic information retrieval system, except as specifically permitted under United States copyright law, without the prior written consent of Respironics.
In the U.S. and Canada
In the U.S. and Canada
Respironics California, Inc.
2271 Cosmos Court
Carlsbad, CA 92011
USA
1-800-345-6443
For Technical support, contact:
Respironics, Inc. Customer Service
Within the U.S.A. 1-800-345-6443
Outside the U.S.A. 724-387-4000
Facsimile 724-387-5012
service@respironics.com
Table of Contents
-
Introduction and Intended Use. ..... 1-1
Recommended Tools and Test Equipment ..... 1-2
Where to Go for Help ..... 1-3 -
Warnings and Cautions ..... 2-1
Warnings ..... 2-1
Cautions ..... 2-2
Notes ..... 2-3 -
Theory of Operation ..... 3-1
Back Panel ..... 3-6
Specifications ..... 3-6
Default Settings ..... 3-6
Settings: CPAP Mode ..... 3-6
Settings: S/T Mode ..... 3-7
Measured Data ..... 3-8
Alarm Settings ..... 3-9
Options ..... 3-9
Nurse Call Station/Serial Communications Connector Pinout ..... 3-10
Physical ..... 3-10
Power ..... 3-11
Triggers and Cycles ..... 3-11
Environmental ..... 3-11
Bacteria Filter ..... 3-12
Date of Manufacture ..... 3-12
Pneumatics ..... 3-13 -
Periodic Maintenance ..... 4-1
Storing the BiPAP Focus ..... 4-2
Cleaning the Reusable Air Inlet Filter ..... 4-2
Replacing the Air Inlet Filter(s) ..... 4-3
Replacing the Battery ..... 4-3 -
Diagnostic Mode and Troubleshooting ..... 5-1
Entering Diagnostic Mode ..... 5-1
Product Information ..... 5-2
System Settings ..... 5-3
Preferences ..... 5-3
Significant Event Log ..... 5-5
Setting Up the Serial Interface for DRPT ..... 5-5
Generating a Diagnostic Report (DRPT) ..... 5-9
Sensor Readings ..... 5-11
System Test ..... 5-15
Significant Event Codes ..... 5-16
-
Ventilator Communications ..... 6-1
Download Service Software to the Service PC ..... 6-1
Installing Communications Software on the Service PC ..... 6-2
Starting the BiPAP Focus Wizard ..... 6-4
Downloading Controller Board Software to the Ventilator ..... 6-4
Downloading UI Software to the Ventilator ..... 6-8
Reprogramming the BiPAP Focus Serial Number ..... 6-13 -
Performance Verification ..... 7-1
Required Test Equipment ..... 7-2
Preliminary Cleaning, Inspection, and Setup ..... 7-3
Electrical Safety Test ..... 7-3
Alarm/LED Test ..... 7-4
BiPAP Focus System Run-in ..... 7-5
Equipment Required ..... 7-5
Procedure ..... 7-5
Real-time Clock Calibration ..... 7-6
Equipment Required ..... 7-6
Procedure ..... 7-6
If Real-Time Clock Calibration Fails ..... 7-8
MFTS Calibration ..... 7-8
Multi Function Test Station Set-up (MFTS) ..... 7-8
MFTS software setup ..... 7-9
Unit Under Test setup ..... 7-10
Calibration ..... 7-11
Field Calibration ..... 7-17
Equipment Required ..... 7-17
Recording Serial Numbers ..... 7-17
Procedure ..... 7-18
Performance Verification ..... 7-28
Procedure ..... 7-28
Performance Verification Data Form ..... 7-29 -
Component Removal/Installation ..... 8-1
Disconnecting Power ..... 8-4
Top Enclosure ..... 8-4
VGA Assembly ..... 8-6
User Interface Board ..... 8-10
Controller PCB ..... 8-11
Valve Assembly ..... 8-13
Blower ..... 8-14
Secondary Alarm ..... 8-15
Primary Alarm ..... 8-16
Main Body Assembly ..... 8-16
Interconnect Diagrams ..... 8-17
9. BiPAP Focus Replacement Parts List ..... 9-1
Complete Parts List ..... 9-1
Exterior ..... 9-3
Exterior (continued) ..... 9-4
Front Panel/User Interface ..... 9-4
Ventilator Interior ..... 9-5
Communications Cables ..... 9-6
Electronic Parts ..... 9-7
Table of Contents
Chapter 1. Introduction and Intended Use
The BiPAP Focus Non-invasive Ventilator is a microprocessor-controlled, electrically powered mechanical ventilator. The BiPAP® Focus™ Ventilator System provides noninvasive ventilation for adult (over 30 kg or 66 lbs.) patients for the treatment of respiratory insufficiency and distress, and obstructive sleep apnea. The BiPAP Focus is appropriate for acute, sub-acute, and intra-hospital transport settings.
The BiPAP Focus System is intended for use with nasal and full face masks. The BiPAP Focus is not intended to be a life-support device.
The BiPAP Focus Ventilator meets or exceeds all applicable safety requirements, consensus guidelines, US regulatory statutes, and international regulatory standards for life support/mechanical ventilation devices.
Read this manual thoroughly prior to performing service or maintenance on the BiPAP Focus Ventilator. This manual contains advanced troubleshooting, calibration, and maintenance instructions for the BiPAP Focus. All maintenance and repair work should be performed by qualified biomedical technicians who have received appropriate training and authorization to provide maintenance, repair, and service for the BiPAP Focus.
Review the operating instructions for the BiPAP Focus Ventilator before running tests, checking operational readiness, or initiating patient use. These instructions include important information about ventilator safety and operation.
For additional information about accessories or related equipment, such as humidifiers and remote alarm systems, refer to the appropriate instruction manual prior to operating with the BiPAP Focus Ventilator.
The BiPAP Focus Operator's Manual for the BiPAP Focus Ventilator lists all applicable warnings and cautions. Review these notices thoroughly before operating the ventilator.
Recommended Tools and Test Equipment
Table 1-1 lists the recommended tools, test equipment, and materials