The main line in from the condensor to the evap coils is frosted bu
The line to the evap coils is frosted but not the evap coils and they aren't cold at all what could be wrong its a frigidaire gallery french door refrigerator
Is dit een goede vraag?
4 opmerkingen
Did you ever get this figured out. Mine seems to be doing the same thing. The line into the evap coil and about a foot of the coil keep freezing, but the freezer cant even freeze ice.
door snorkelne1
Snorkeine1-this is a problem in your sealed system. You either have a restriction or a leak. The only way to be sure is to tap into the sealed system. This should be done by a certified refrigeration technician only. There are procedures that need to be done per the EPAs guidelines.
door LadyTech
How much would that cost approx?
I'm ready to just move on to a new unit at this point. Sealed system sounds expensive.
door snorkelne1
Snorkelne1 - It depends a lot on where you live. In Texas where I’m at, the lowest labor cost I’ve heard is $350. The doesn’t include parts. Leaks could be anywhere but i see them mostly in the condenser. Condenser prices vary )$100-$200. You want an experienced technician to do the repairs. Consumers have a right to ask technicians to show them their credentials. They should carry their Certification, State registration and EPA cards with them.
door LadyTech