Ga door naar hoofdinhoud

Repair information and guides for the iPhone 6 that was released on September 19, 2014. Model Numbers: A1549, A1586, and A1589

4994 Vragen Bekijk alle

Screen Goes Blank When Home Button/Heat Shield Flex Is Plugged In

Hi

Device I traded in with broken/cracked LCD showed no signs of life.

An lcd and battery change has got phone working however a strange issue I'm wondering if anyone has experienced before.

When I connect home button/heat shield flex to the board the screen goes black.

Presumed there was an issue with flex but is is the same once replaced and the same with other lcds.

Any tips be appreciated, I'm guessing pointing towards board FPC issue.

*UPDATE: Error disappears when home button is unplugged from shield.

Beantwoord! Bekijk het antwoord Dit probleem heb ik ook

Is dit een goede vraag?

Score 0
Voeg een opmerking toe

1 Antwoord

Gekozen oplossing

You definitely need to inspect the Home button FPC on the logic board. It could be damaged and shorting out. But it could also be a defective Home Button that is shorting the circuit. If the FPC looks good and there are no issues with the surrounding components, then I would try to install a "regular" Home button (Touch ID will not work). If that solves the problem, it is either the button or the Mesa circuit (which drives TouchID functionality).

Ultimately, the logic board will have to be tested by a micro-solderer to understand the root cause. If it is the MESA circuit, that can be repaired to restore Touch ID.

Was dit antwoord nuttig?

Score 2

3 opmerkingen:

Just tried a spare home button which sorted the issue. Thanks, a device without touch id will do for now

door

Even better cleaned the old home button connection and all is working fine. Thanks

door

Awesome! Congrats!

door

Voeg een opmerking toe

Voeg je antwoord toe

Niall zal eeuwig dankbaar zijn.
Weergavestatistieken:

Afgelopen 24 uren: 0

Afgelopen 7 dagen: 0

Afgelopen 30 dagen: 0

Altijd: 56