Ga door naar hoofdinhoud
Help

Deze versie is geschreven door: Ben H.

Titel:

Air in system icon displayed. Purging air just fills drip tray.

Tekst:

Melitta Caffeo Solo (late 2020 model).
Was working perfectly until a few days ago when the 'Air in the system' icon appeared on the display. I checked the manual and pressed the bean button (coffee strength) to purge air from the system.
The pump runs for about a minute and when the process completes, the icon remains illuminated. I followed this same procedure multiple times but the drip tray just fills with clean water.[br]
[br]
I read a post somewhere online that said a likely (and common) culprit was a failed drainage valve.
After following the iFixit guide, I thoroughly cleaned the main unit and looked for any failed/ broken parts. Everything looked fine.
I replaced the drainage valve with a new Melitta part, lubricating all of the valve gaskets and the white plastic actuator in the back of the brewing unit area with a light coat of silicone grease. The actuator was installed using the markings on the cover as advised in the guide. No cables were disconnected or damaged.
Upon reassembly and after a factory reset, the same issue persists.
I've also followed the iFixit guide to dismantle and thoroughly clean the brewing unit and see if a gasket had failed or if there was a blockage. There wasn't - everything looked fine.
Can anyone help?
———
ADDITIONAL INFO:
Unit is regularly cleaned with Melitta products and has been descaled with Durgol descaler.[br]
[br]
With the brewing module side cover off, the startup/ shutdown procedures seems to still move the parts of the brewing module.
=== Update (08/23/2022) ===
-
Spoke to the Melitta engineer at Coffee Classics (UK) and he's suggested that I replace the flow meter.
-
-If you have a new model Solo (2021+ with the grey grinder) you need part number: 6761334. It's about £5.99 in 2022. If you have the old model Solo (<2020 with the cream colour grinder) you need part number: 6556419. It's about £5.60 in 2022.
The engineer has speculated that if replacing the flow meter doesn't resolve the issue, it could be the logic board which would make the unit uneconomical to repair.
-=== Update (08/23/2022) ===
-
+=== Update (09/05/2022) ===
Success! It was the flow meter. Now drinking my favourite brew again.

Toestel:

Melitta Caffeo Solo

Status:

open

Goedgekeurd antwoord:

746543

Bewerkt door: Ben H.

Titel:

Air in system icon displayed. Purging air just fills drip tray.

Tekst:

Melitta Caffeo Solo (late 2020 model).
Was working perfectly until a few days ago when the 'Air in the system' icon appeared on the display. I checked the manual and pressed the bean button (coffee strength) to purge air from the system.
The pump runs for about a minute and when the process completes, the icon remains illuminated. I followed this same procedure multiple times but the drip tray just fills with clean water.[br]
[br]
I read a post somewhere online that said a likely (and common) culprit was a failed drainage valve.
After following the iFixit guide, I thoroughly cleaned the main unit and looked for any failed/ broken parts. Everything looked fine.
I replaced the drainage valve with a new Melitta part, lubricating all of the valve gaskets and the white plastic actuator in the back of the brewing unit area with a light coat of silicone grease. The actuator was installed using the markings on the cover as advised in the guide. No cables were disconnected or damaged.
Upon reassembly and after a factory reset, the same issue persists.
I've also followed the iFixit guide to dismantle and thoroughly clean the brewing unit and see if a gasket had failed or if there was a blockage. There wasn't - everything looked fine.
Can anyone help?
———
ADDITIONAL INFO:
Unit is regularly cleaned with Melitta products and has been descaled with Durgol descaler.[br]
[br]
With the brewing module side cover off, the startup/ shutdown procedures seems to still move the parts of the brewing module.
=== Update (08/23/2022) ===
Spoke to the Melitta engineer at Coffee Classics (UK) and he's suggested that I replace the flow meter.
If you have a new model Solo (2021+ with the grey grinder) you need part number: 6761334. It's about £5.99 in 2022. If you have the old model Solo (<2020 with the cream colour grinder) you need part number: 6556419. It's about £5.60 in 2022.
The engineer has speculated that if replacing the flow meter doesn't resolve the issue, it could be the logic board which would make the unit uneconomical to repair.
+
+=== Update (08/23/2022) ===
+
+Success! It was the flow meter. Now drinking my favourite brew again.

Toestel:

Melitta Caffeo Solo

Status:

open

Goedgekeurd antwoord:

746543

Bewerkt door: Ben H.

Titel:

Air in system icon displayed. Purging air just fills drip tray.

Tekst:

Melitta Caffeo Solo (late 2020 model).
Was working perfectly until a few days ago when the 'Air in the system' icon appeared on the display. I checked the manual and pressed the bean button (coffee strength) to purge air from the system.
The pump runs for about a minute and when the process completes, the icon remains illuminated. I followed this same procedure multiple times but the drip tray just fills with clean water.[br]
[br]
I read a post somewhere online that said a likely (and common) culprit was a failed drainage valve.
After following the iFixit guide, I thoroughly cleaned the main unit and looked for any failed/ broken parts. Everything looked fine.
I replaced the drainage valve with a new Melitta part, lubricating all of the valve gaskets and the white plastic actuator in the back of the brewing unit area with a light coat of silicone grease. The actuator was installed using the markings on the cover as advised in the guide. No cables were disconnected or damaged.
Upon reassembly and after a factory reset, the same issue persists.
I've also followed the iFixit guide to dismantle and thoroughly clean the brewing unit and see if a gasket had failed or if there was a blockage. There wasn't - everything looked fine.
Can anyone help?
———
ADDITIONAL INFO:
Unit is regularly cleaned with Melitta products and has been descaled with Durgol descaler.[br]
[br]
With the brewing module side cover off, the startup/ shutdown procedures seems to still move the parts of the brewing module.
+
+=== Update (08/23/2022) ===
+
+Spoke to the Melitta engineer at Coffee Classics (UK) and he's suggested that I replace the flow meter.
+
+If you have a new model Solo (2021+ with the grey grinder) you need part number: 6761334. It's about £5.99 in 2022. If you have the old model Solo (<2020 with the cream colour grinder) you need part number: 6556419. It's about £5.60 in 2022.
+
+The engineer has speculated that if replacing the flow meter doesn't resolve the issue, it could be the logic board which would make the unit uneconomical to repair.

Toestel:

Melitta Caffeo Solo

Status:

open

Goedgekeurd antwoord:

746543

Bewerkt door: Ben H.

Titel:

Air in system icon displayed. Purging air just fills drip tray.

Tekst:

Melitta Caffeo Solo (late 2020 model).

Was working perfectly until a few days ago when the 'Air in the system' icon appeared on the display. I checked the manual and pressed the bean button (coffee strength) to purge air from the system.

The pump runs for about a minute and when the process completes, the icon remains illuminated. I followed this same procedure multiple times but the drip tray just fills with clean water.[br]
[br]
I read a post somewhere online that said a likely (and common) culprit was a failed drainage valve.

After following the iFixit guide, I thoroughly cleaned the main unit and looked for any failed/ broken parts. Everything looked fine.

I replaced the drainage valve with a new Melitta part, lubricating all of the valve gaskets and the white plastic actuator in the back of the brewing unit area with a light coat of silicone grease. The actuator was installed using the markings on the cover as advised in the guide. No cables were disconnected or damaged.

Upon reassembly and after a factory reset, the same issue persists.

I've also followed the iFixit guide to dismantle and thoroughly clean the brewing unit and see if a gasket had failed or if there was a blockage. There wasn't - everything looked fine.

Can anyone help?

———

ADDITIONAL INFO:

Unit is regularly cleaned with Melitta products and has been descaled with Durgol descaler.[br]
[br]
With the brewing module side cover off, the startup/ shutdown procedures seems to still move the parts of the brewing module.

Toestel:

Melitta Caffeo Solo

Status:

open

Goedgekeurd antwoord:

+746543

Bewerkt door: Ben H.

Titel:

Air in system icon displayed. Purging air just fills drip tray.

Tekst:

Melitta Caffeo Solo (late 2020 model).
Was working perfectly until a few days ago when the 'Air in the system' icon appeared on the display. I checked the manual and pressed the bean button (coffee strength) to purge air from the system.
The pump runs for about a minute and when the process completes, the icon remains illuminated. I followed this same procedure multiple times but the drip tray just fills with clean water.[br]
[br]
I read a post somewhere online that said a likely (and common) culprit was a failed drainage valve.
After following the iFixit guide, I thoroughly cleaned the main unit and looked for any failed/ broken parts. Everything looked fine.
I replaced the drainage valve with a new Melitta part, lubricating all of the valve gaskets and the white plastic actuator in the back of the brewing unit area with a light coat of silicone grease. The actuator was installed using the markings on the cover as advised in the guide. No cables were disconnected or damaged.
Upon reassembly and after a factory reset, the same issue persists.
-I've also dismantled, cleaned and lubricated (with silicone grease) the main components of the brewing unit to see if a gasket had failed or if there was a blockage. There wasn't.
+I've also followed the iFixit guide to dismantle and thoroughly clean the brewing unit and see if a gasket had failed or if there was a blockage. There wasn't - everything looked fine.
Can anyone help?
———
ADDITIONAL INFO:
Unit is regularly cleaned with Melitta products and has been descaled with Durgol descaler.[br]
[br]
With the brewing module side cover off, the startup/ shutdown procedures seems to still move the parts of the brewing module.

Toestel:

Melitta Caffeo Solo

Status:

open

Bewerkt door: Ben H.

Titel:

-Air in system icon displayed. Water just fills drip tray. Help!
+Air in system icon displayed. Purging air just fills drip tray.

Tekst:

Melitta Caffeo Solo (late 2020 model).
Was working perfectly until a few days ago when the 'Air in the system' icon appeared on the display. I checked the manual and pressed the bean button (coffee strength) to purge air from the system.
The pump runs for about a minute and when the process completes, the icon remains illuminated. I followed this same procedure multiple times but the drip tray just fills with clean water.[br]
[br]
I read a post somewhere online that said a likely (and common) culprit was a failed drainage valve.
After following the iFixit guide, I thoroughly cleaned the main unit and looked for any failed/ broken parts. Everything looked fine.
I replaced the drainage valve with a new Melitta part, lubricating all of the valve gaskets and the white plastic actuator in the back of the brewing unit area with a light coat of silicone grease. The actuator was installed using the markings on the cover as advised in the guide. No cables were disconnected or damaged.
Upon reassembly and after a factory reset, the same issue persists.
+I've also dismantled, cleaned and lubricated (with silicone grease) the main components of the brewing unit to see if a gasket had failed or if there was a blockage. There wasn't.
+
Can anyone help?
———
ADDITIONAL INFO:
Unit is regularly cleaned with Melitta products and has been descaled with Durgol descaler.[br]
[br]
With the brewing module side cover off, the startup/ shutdown procedures seems to still move the parts of the brewing module.

Toestel:

Melitta Caffeo Solo

Status:

open

Origineel bericht door: Ben H.

Titel:

Air in system icon displayed. Water just fills drip tray. Help!

Tekst:

Melitta Caffeo Solo (late 2020 model).

Was working perfectly until a few days ago when the 'Air in the system' icon appeared on the display. I checked the manual and pressed the bean button (coffee strength) to purge air from the system.

The pump runs for about a minute and when the process completes, the icon remains illuminated. I followed this same procedure multiple times but the drip tray just fills with clean water.[br]
[br]
I read a post somewhere online that said a likely (and common) culprit was a failed drainage valve.

After following the iFixit guide, I thoroughly cleaned the main unit and looked for any failed/ broken parts. Everything looked fine.

I replaced the drainage valve with a new Melitta part, lubricating all of the valve gaskets and the white plastic actuator in the back of the brewing unit area with a light coat of silicone grease. The actuator was installed using the markings on the cover as advised in the guide. No cables were disconnected or damaged.

Upon reassembly and after a factory reset, the same issue persists.

Can anyone help?

———

ADDITIONAL INFO:

Unit is regularly cleaned with Melitta products and has been descaled with Durgol descaler.[br]
[br]
With the brewing module side cover off, the startup/ shutdown procedures seems to still move the parts of the brewing module.

Toestel:

Melitta Caffeo Solo

Status:

open